BGTJN - FE-7004-A RESIWELD/FOUND IN KIT 307R592601/

  • MSDS: BGTJN
  • Manufacturer: H B FULLER CO
  • Product Name: FE-7004-A RESIWELD/FOUND IN KIT 307R592601/
  • National Stock Number: 8040-00-062-4173
Product Identification

Product ID:FE-7004-A RESIWELD/FOUND IN KIT 307R592601/
MSDS Date:06/09/1989
FSC:8040
NIIN:00-062-4173
Kit Part:Y
MSDS Number: BGTJN

Responsible Party
H.B. FULLER CO.
1200 WOLTERS BOULEVARD
VADNALIS HEIGHT, MN 55110
US

Emergency Phone: 612-481-3300 OR 612-488-1588

Info Phone: 612-481-3300

Preparer: JOHN DOLMER,CIH

Cage: DO317

Contractor
H.B. FULLER COMPANY
ST. PAUL, MN 55126-8076 US

Telephone: 612-236-5300/ -5309 FAX

Cage: 0DH19

Ingredients

N-BUTYL GLYCIDYL ETHER (BGE)

CAS: 2426-08-6

RTECS: TX4200000

Fraction By Weight: 1-10%.

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM; 9293


EPOXY RESIN

Fraction By Weight: >10%.

OSHA PEL NONE ESTABLISHED

ACGIH TLV: NONE ESTABLISHED


SILICA,AMORPHOUS (WILL NOT PRESENT AN EXPOSURE RISK DURING

CAS: 7631-86-9

Fraction By Weight: 1.-10%.

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3


PRODUCT IS LIQUID. ONCE DRIED & IS ABRADED OR DISTURBED,

RTECS: 9999999ZZ


90 GM VOC/LITER OF MATERIAL

RTECS: 9999999VO

Hazards

LD50 LC50 Mixture:NO INFORMATION PROVIDED
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: RESPIRATORY & EYE IRRITANT;
BUTYL GLYCIDYL ETHER IS A DERMAL SENSITIZER. CHRONIC:NONE
ANTICIPATED.
Explanation of Carcinogenicity:NR
Effects of Overexposure:EYES:DIRECT CONTACT MAY CAUSE IRRITATION; SKIN:
BUTYL GLYCIDYL ETHER IS A DERMAL SENSITIZER; INHAL:VAPORS MAY CAUSE
RESPIRATORY IRRITATION.
Medical Cond Aggravated by Exposure:NO KNOWN EFFECTS ON OTHER
ILLNESSES.

First Aid

First Aid:EYES:FLUSH IMMEDIATELY W/ WATER FOR 15 MINS. GET MED ATTN. IF
IRRITATION PERSISTS; SKIN:WASH AFFECTED AREA W/SOAP & WATER.
LAUNDER CONTAMINATED CLOTHING BEFORE REUSE; INHAL:REMOVE FROM
EXPOSURE. RESTO RE BREATHING IF NECESSARY. KEEP WARM & QUIET. GET
MED ATTN.

Fire Fighting

Flash Point Method:SCC
Flash Point:100-199F
Extinguishing Media:USE WATER SPRAY,FOAM,DRY CHEMICAL OR CARBON
DIOXIDE.
Fire Fighting Procedures:PERSONS EXPOSED TO PRODUCTS OF COMBUSTION
SHOULD WEAR SELF-CONTAINED BREATHING APPARATUS & FULL PROTECTIVE
EQUIPMENT.
Unusual Fire/Explosion Hazard:NONE KNOWN.

Accidental Release

Spill Release Procedures:WEAR RUBBER GLOVES & WIPE UP W/INERT ABSORBENT
MATERIAL. RESIDUE MAY BE REMOVED W/CHLORINATED SOLVENTS.

Handling

Handling and Storage Precautions:STORE IN COOL,DRY LOCATION. AVOID SKIN
CONTACT W/PRODUCT AT ALL TIMES.
Other Precautions:USE MATERIAL IN MANNER PROVIDED BY INSTRUCTIONS.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS DO NOT MAINTAIN
INHALATION EXPOSURES BELOW PEL/TLV, USE NIOSH/MSHA APPROVED
RESPIRATOR AS PER CURRENT 29CFR1910.134, INSTRUCTIONS/WARNINGS &
NIOSH-RESPIRATOR DECISION LOGIC-PUB #87-108.
Ventilation:PROVIDE SUFFICIENT GENERAL/LOCAL EXHAUST VENTILATION IN
PATTERN/VOLUME TO CONTROL INHALATION EXPOSURES BELOW PEL/TLV.
Protective Gloves:IMPERVIOUS TYPE FOR TASK AT HAND.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:AS REQUIRED FOR TASK AT HAND TO MINIMIZE
EXPOSURE & ENHANCE WORKER PROTECTION (EG. EYE-WASH STATION, ETC).
Work Hygienic Practices:USE IN MANNER SET FORTH BY MFR'S DIRECTIONS AS
WELL AS PROCEDURES SET FORTH BY SAFETY & HEALTH OFFICE.
Supplemental Safety and Health
WARNING STATEMENTS: VAPORS HARMFUL-DERMAL SENSITIZER. KEY1:N1.

Chemical Properties

Spec Gravity:1.15
Viscosity:3500 CPS
Appearance and Odor:LIQUID.
Percent Volatiles by Volume:N/E

Stability

Stability Indicator/Materials to Avoid:YES
NONE ESTABLISHED.
Stability Condition to Avoid:MFR CITES NONE.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN YIELD LOW
MOLECULAR WEIGHT HYDROCARBONS, CARBON MONOXIDE.

Disposal

Waste Disposal Methods:PRODUCT DOES NOT MEET HAZ WASTE DEFIN UNDER
40CFR261(RCRA). STATE OR LOCAL HAZ WASTE REGULATIONS IF DIFFERENT
FROM FED REGS. INCINERATE OR DISPOSE OF IN AN APPRVD INDUSTRIAL
LANDFILL.FOR ADDITIONAL AS SISTANCE,CONTACT 612-481-1588.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.